What is a modular cleanroom? General

A modular cleanroom uses prefabricated wall, door and technical elements to create a controlled environment. The required ISO classification, airflow, pressure concept and testing scope depend on the process. PURAXI designs modular ISO 7 and ISO 8 cleanroom concepts for new and existing buildings.

How much does a cleanroom cost per square meter? General

Cleanroom cost depends on ISO class, surface area, room height, finish level, HVAC design, validation scope and industry requirements. A basic ISO 8 cleanroom is typically less expensive than a GMP or ISO 5 environment with strict temperature and humidity control. A realistic estimate requires a short review of the process, room and required standard.

How long does it take to build a cleanroom? General

Timelines depend on design maturity, existing conditions, HVAC and process interfaces, installation and qualification requirements. Modular preparation can help simplify certain project stages; PURAXI defines a realistic schedule after reviewing the scope.

Which ISO class do I need for my application? General

The right ISO class depends on your product, process and contamination risk. Many controlled production environments use ISO 8 or ISO 7, while aseptic production or sensitive microelectronics may require stricter classes. The final classification should be based on a risk assessment, sector standards and validation strategy.

Can a cleanroom be installed in an existing building? General

Many existing buildings can accommodate a modular cleanroom, including sites with limited ceiling height. Feasibility depends on available space, building services, structure, fire safety and the intended cleanroom classification. PURAXI evaluates these constraints before selecting a side-plenum configuration.

What is a cleanroom and how does it work? General

A cleanroom is a controlled environment where airborne particles, microorganisms, temperature, humidity and pressure are managed. Air is filtered through HEPA or ULPA filters and continuously refreshed to reduce contamination. Cleanrooms are used in pharma, medtech, electronics, laboratories and precision manufacturing.

What is a cleanroom used for? General

Cleanrooms are used when dust, particles or microbiological contamination can damage a product or process. Typical applications include pharmaceutical production, medical devices, electronics, optics, laboratories, supplements and precision assembly. Requirements vary strongly by industry and risk level.

What is the difference between a cleanroom and a hygienic room? General

A hygienic room is mainly designed for cleaning, hygiene and reduced cross-contamination. A cleanroom goes further by controlling airborne particles, pressure differences, airflow and measurable air cleanliness. Not every hygienic room is a cleanroom.

How many air changes per hour are required per ISO class? Technical

The required air changes per hour depend on ISO class, occupancy, heat load, process and contamination source. ISO 8 usually needs fewer air changes than ISO 7, while ISO 5 may require much higher airflow or local laminar flow. The exact value should come from design calculations and validation, not only from a fixed table.

Which validation or certification is required for a cleanroom? Technical

ISO 14644 covers cleanroom classification and related testing. In regulated sectors, the project may also require commissioning, qualification and a broader quality-system approach. The scope of IQ, OQ and PQ depends on the intended use and customer requirements.

What does GMP mean for cleanrooms? Technical

GMP means Good Manufacturing Practice and defines quality rules for regulated production. In cleanrooms, GMP covers more than air cleanliness: it also includes procedures, documentation, cleaning, validation, risk control and personnel flow. A GMP cleanroom must therefore be technically and procedurally controlled.

What are IQ, OQ and PQ? Technical

Installation Qualification (IQ) documents correct installation against the specification. Operational Qualification (OQ) verifies operation against defined limits. Performance Qualification (PQ) demonstrates performance under specified operating conditions, where required.

What is overpressure in a cleanroom? Technical

Overpressure means that the cleanroom air pressure is higher than the pressure in adjacent areas. When a door opens, air flows out instead of allowing unfiltered air to enter. Overpressure is often used to protect the product from contamination.

What is the difference between ISO class 5, 7 and 8? Technical

ISO classes define how many particles are allowed per cubic meter of air. ISO 5 is much stricter than ISO 7 and ISO 8 and is used for highly sensitive processes. ISO 7 and ISO 8 are common in pharma, medtech and industrial production environments.

What is laminar airflow? Technical

Laminar airflow is a controlled air movement where filtered air travels in one main direction, often vertically from top to bottom. It helps move particles away from critical work zones. Laminar flow is mainly used for sensitive processes such as aseptic handling, sterile production or fine assembly.

When is laminar flow required? Technical

Laminar flow is required when the product or process needs direct protection from contamination. Examples include open product contact, sterile operations, sensitive electronics and high-cleanliness laboratory work. Not every cleanroom needs full laminar flow; local protection above critical zones is often enough.

What is the difference between a cleanroom and a cleanzone? Technical

A cleanroom is a full room classified to a specific ISO cleanliness level. A cleanzone is a defined area inside a room where local air cleanliness is improved, often with laminar flow or a filter module. Cleanzones are useful when only one process area needs extra protection.

What is ISO 14644? Technical

ISO 14644 is the international standard for cleanrooms and controlled environments. It describes how particle concentration is measured and how cleanrooms are classified. ISO 14644 is used in pharma, medtech, electronics, laboratories and other controlled industries.

What is a HEPA filter? Technical

A HEPA filter is a high-efficiency filter that removes very small particles from the air. Cleanrooms often use H13 or H14 filters, depending on the application and standard. HEPA filters are essential for maintaining controlled particle concentrations.

What is underpressure in a cleanroom? Technical

Underpressure means that the room pressure is lower than the pressure in adjacent areas. It is used when the surrounding environment must be protected from substances or microorganisms inside the room. Underpressure is common in certain laboratories, isolation rooms and hazardous processes.

What are the advantages of side-plenum airflow? Side-plenum & airflow

Side-plenum cleanroom systems can reduce the need for an overhead air-distribution plenum and offer flexible layouts in existing buildings. Airflow distribution, local air velocity, temperature and acoustics must still be engineered for the process and operator comfort; a side plenum alone does not guarantee better comfort.

What is a side-plenum cleanroom? Side-plenum & airflow

A side-plenum cleanroom integrates part of its air supply and return path into wall-side modules rather than relying entirely on an overhead air-distribution plenum. PURAXI uses this approach in selected modular ISO 7 and ISO 8 configurations. Filtration, airflow, building-service interfaces and room performance are defined for each project.

What is the disadvantage of a ceiling plenum cleanroom? Side-plenum & airflow

A ceiling plenum cleanroom needs a technical void above the cleanroom for airflow, ducting and filter infrastructure. This reduces usable room height and can make installation difficult in existing buildings, mezzanines or low-ceiling spaces. It also places critical technical infrastructure directly above the cleanroom and work area.

Is a ceiling plenum always allowed above a cleanroom? Side-plenum & airflow

Not always. A ceiling plenum must be assessed for cleanability, leakage risk, maintenance access, fire safety, occupational comfort and regulatory expectations. In many projects, a technical plenum above the cleanroom becomes difficult to justify because it introduces hidden spaces and infrastructure above the controlled work area.

What are the cleanroom requirements for the pharmaceutical industry? By sector

Pharmaceutical cleanrooms must meet strict requirements for air quality, pressure cascade, cleanability, documentation and validation. ISO 14644 is often combined with GMP guidance. The exact requirements depend on the product, process and whether production is sterile or non-sterile.

What are the cleanroom requirements for electronics and semiconductors? By sector

Electronics and semiconductor cleanrooms focus on particle control, electrostatic control, temperature, humidity and process stability. Even very small particles can damage components or wafers. These environments often require stricter ISO classes and carefully controlled airflow.

Which cleanroom standards apply to medical devices? By sector

Medical device production often uses ISO 14644 together with quality systems such as ISO 13485. The cleanroom must show that production happens in a controlled environment suitable for the contamination risk of the device. Validation, monitoring and documentation are important parts of compliance.

Which cleanroom is needed for supplements or nutraceuticals? By sector

Supplements often require a controlled hygienic production environment, sometimes supported by ISO 8 or ISO 7 depending on product risk. Key concerns include dust control, cross-contamination, cleanability and air handling. Requirements are usually less strict than sterile pharma but still need to be demonstrably controlled.

Which cleanroom is needed for laboratories? By sector

Laboratories may need cleanrooms for analysis, microbiology, R&D or sensitive experiments. Requirements depend on the research type, contamination risk and target ISO class. Sometimes a full cleanroom is required, while in other cases a cleanzone or laminar flow cabinet is enough.

Which cleanroom is needed for medical packaging? By sector

Medical packaging often requires a controlled environment to prevent contamination of packaging materials or finished products. ISO 7 or ISO 8 is common, depending on risk and final use. Validation and traceability are important for quality assurance.

Can a cleanroom be expanded? Practical

Yes, a modular cleanroom can usually be expanded more easily than a traditional construction. Additional panels, doors, filters or technical modules can often be added without a full rebuild. This makes modular cleanrooms useful for companies that expect growth or changing production volumes.

Does PURAXI deliver turnkey cleanroom projects? Practical

PURAXI can discuss integrated project delivery covering design, installation and agreed testing and documentation. Exact responsibilities and qualification scope are defined in the project proposal.

Does PURAXI work internationally? Practical

PURAXI supports cleanroom projects across Europe. Engineering, installation approach, documentation and project responsibilities are defined according to the requirements and location of each project.

How do I start a cleanroom project? Practical

A cleanroom project starts with the application, target ISO class, surface area, process flow, sector and available space. The next steps are concept design, technical sizing, budget estimate and validation planning. The clearer the input, the faster a reliable scope and schedule can be prepared.

Can a cleanroom be built without a ceiling plenum? Practical

Yes. Depending on the application, a cleanroom may use side-plenum air distribution instead of a conventional ceiling air-distribution plenum. This can preserve valuable space in buildings with limited headroom. Other ceiling, ventilation, fire-safety and maintenance requirements still need to be assessed.

Can a cleanroom be relocated? Practical

A modular cleanroom can often be dismantled and rebuilt at another location. Not every part is always reusable one-to-one, but the main structure is much more flexible than traditional construction. After relocation, the cleanroom must be validated again.

What maintenance does a cleanroom need? Practical

Cleanroom maintenance includes filter checks, pressure measurements, airflow tests, cleaning, wall and door inspections and periodic requalification. Temperature, humidity and particle monitoring may also be required. Good maintenance prevents performance loss and helps keep the cleanroom validated.

How often should a cleanroom be revalidated? Practical

Revalidation frequency depends on the sector, ISO class, regulation and internal quality procedures. Many cleanrooms are checked annually or twice per year, while critical environments may require more frequent testing. Requalification is also needed after modifications, relocation or technical interventions.

What information does PURAXI need for a quotation? Practical

For a first quotation, PURAXI needs surface area, room height, target ISO class, sector, location, process description and any GMP or validation requirements. Existing plans or photos of the space are also very helpful. Based on this, PURAXI can prepare an indicative scope, budget and timing.

Is a modular cleanroom suitable for small rooms? Practical

Normal cleanroom systems are often difficult to use in small rooms because technical ceilings, ductwork and limited height take up too much space. PURAXI is designed to work in compact or existing rooms through a side-plenum approach without a classic ceiling plenum. This can make an ISO 7/8 cleanroom feasible where conventional systems are too large or too complex.

Can PURAXI build affordable cleanrooms for startups? Startups & budget

Yes, PURAXI can help startups build a practical first cleanroom or controlled environment without over-engineering the project. The focus is on a technically correct, affordable and scalable solution that matches the real process risk. A modular cleanroom can start small and grow with the company as production, testing or validation needs increase.

Do startups always need a fully certified cleanroom? Startups & budget

Not always. Some startups need a fully classified and validated cleanroom, while others can begin with a controlled environment, cleanzone or pilot cleanroom. The right choice depends on product risk, customer requirements, regulatory expectations and the stage of development.

What is the smallest cleanroom a startup can build? Startups & budget

The smallest cleanroom depends on the process, equipment, operator flow and required ISO class. In many cases, a compact modular cleanroom or cleanzone can be enough for R&D, testing, packaging or small-batch production. PURAXI can help define the minimum viable cleanroom without creating future limitations.

Can a cleanroom start as a pilot room and later become a production room? Startups & budget

Yes, a modular cleanroom can often start as a pilot or R&D room and later be expanded or upgraded for production. This is useful for startups that need to prove a process before investing in a larger facility. The key is to design the first phase with future expansion in mind.

How can I reduce the cost of a cleanroom project? Startups & budget

Cleanroom cost can be reduced by choosing the right ISO class, avoiding unnecessary over-specification, limiting the clean area to the real process zone and using a modular system. Early design decisions have the biggest impact on cost. A good cleanroom concept should reduce complexity without compromising the required performance.

What is the risk of over-engineering a cleanroom? Startups & budget

Over-engineering a cleanroom can make the project more expensive, slower and harder to operate than necessary. It can also increase energy use, maintenance and validation workload. The best cleanroom is not always the strictest one; it is the one that matches the real contamination risk.

Can PURAXI help if we do not know which cleanroom we need? Startups & budget

Yes, PURAXI can help translate an early process idea into practical cleanroom requirements. This includes ISO class, room size, airflow concept, pressure strategy, materials, validation level and possible expansion. This is especially useful for startups or companies building their first controlled environment.

Is a cleanroom always necessary, or is a cleanzone enough? Startups & budget

A full cleanroom is not always necessary. If only one process step or work area needs protection, a cleanzone or local laminar flow solution may be enough. Choosing between a cleanroom and a cleanzone depends on product risk, workflow, contamination sources and validation expectations.

What is the difference between a cleanroom and a dry room? Battery & advanced manufacturing

A cleanroom controls airborne particles and contamination. A dry room controls humidity, often to very low dew points, and may also include cleanroom-level particle control. Battery production, moisture-sensitive materials and certain electronics processes may require dry room conditions instead of, or in addition to, cleanroom classification.

Which cleanroom is needed for battery production? Battery & advanced manufacturing

Battery production often requires a controlled environment to manage particles, humidity, temperature and process contamination. The exact requirements depend on whether the process involves cell assembly, module assembly, testing, packaging or R&D. Some battery processes require very low humidity dry rooms, while others can use ISO-classified cleanrooms or controlled zones.

Does battery manufacturing always require a dry room? Battery & advanced manufacturing

No, not every battery-related process requires a full dry room. Lithium-ion cell production often needs very low humidity, especially when moisture-sensitive materials are exposed. Other steps, such as module assembly, testing or certain R&D activities, may require particle control, local clean zones or a standard cleanroom instead.

Can PURAXI build cleanrooms for pilot production? Battery & advanced manufacturing

Yes, PURAXI can build modular cleanrooms for pilot production, small-batch manufacturing and process validation. Pilot cleanrooms are useful when a company needs controlled conditions before scaling to full production. A modular system can be designed so the pilot phase supports future growth.